Industrial Edge Monitoring Platform (Kit 2)
- Discounted price:US$
- Sale US$
- MSRP US$
- Use bonus pointspt.
- Modbus TCP Client and Modbus RTU Master for data acquisition from PLCs, meters and sensors
- Up to 300 local tags per gateway
- Authenticated REST API for integration with MES, ERP, BI and analytics applications
- Modbus TCP Server for data exchange with SCADA, HMI and PLC systems (K2, K3)
- Web-based local dashboard, virtual tags, historical trends and graphic view, enabled by software kit
- Mobile monitoring and push notifications for iOS and Android
- Licensed local functions operate independently of LESI CLOUD services
- Web-based configuration over HTTPS; no PC utility required
- Fanless design in a 40 mm wide polycarbonate housing for 35 mm DIN-rail mounting
- 24 VDC input with protective earth terminal; battery-backed real-time clock
-
Where Each Kit FitsThree applications the same gateway covers — and the level each one usually needs.
Remote machine monitoring1Remote Machine Status Monitoring
PLCs, counters and cycle-time data that the shift can check from any phone — run, idle, alarm.
K1Eyes on the floor. Nothing upstream needs the data yet.
OUTCOMES- ✓Faster response to downtime
- ✓Machine-state and cycle-time data to support OEE analysis
- ✓Line visibility without a PC on the floor
Does anyone outside the plant floor need this data?
NO → K1A screen and a phone are enough.
Remote energy monitoring2Remote Energy Monitoring Across Panels
Main meters, panel sub-meters and machine-level power, totalled and handed to the systems that report on them.
K2Virtual Tags total the meters; REST and Modbus Server feed the report.
OUTCOMES- ✓Identify abnormal energy peaks sooner
- ✓See usage by zone or machine
- ✓Energy figures reach ERP or BI without middleware
Does another system — MES, ERP, BI, SCADA — need to read it?
YES → K2REST Out, Modbus Server, Virtual Tags.
Remote utility & environmental3Remote Utility & Environmental Monitoring
Temperature, humidity, pH, flow and level across tanks, pumps and treatment stages.
K3A process reads better as a plant picture — and excursions need trends on site.
OUTCOMES- ✓Spot excursions sooner
- ✓Fewer manual round checks
- ✓Local trend history for on-site investigation
Do operators need trend history and a plant picture on site?
YES → K3Local trends and Graphic View.
⛨FOR INTEGRATORS
& MACHINE BUILDERSWiring a panel is the easy part. Handing over a dashboard, an API and a mobile app on the same day is not. LESI lets you engineer the whole monitoring scope — on a retrofit project or built into every machine you ship — while installation, configuration and integration revenue stays yours.
-
K2 KIT 02INTEGRATION KIT · MOST DEPLOYEDBring Equipment Data Into Your Own SystemsEverything in K1, plus the three things an integrator usually needs on site: a dashboard served by the gateway itself, calculated tags, and a Modbus Server so the SCADA or HMI already on the panel can read what LESI collects.✓Everything in K1 included ▭Local dashboard ⇄Virtual tags ▣Modbus ServerEDG-DASH Local Web dashboard on the gateway

Actual on-device dashboard, shown in an example configuration. Live values grouped by area or machine; out-of-range tags flag themselves. Opened from any browser on the plant network — no cloud in the path.
WHO IT’S FORIntegrators and plant engineers who need equipment data inside SCADA, HMI, MES or ERP.
▭Local Dashboard
Live tiles grouped by line, area or equipment. One URL for the office PC, the panel display and the tablet on the floor.
EDG-DASH⇄Virtual Tags
Total meters, convert units, derive condition flags — calculated at the gateway, so every consumer reads the same number.
EDG-VTAG▣Modbus Server
Map configured tags to registers and let an existing SCADA, HMI or PLC poll the gateway — no middleware to write.
EDG-MBSRV⌬Upstream systems can take either road: Modbus Server for the plant-floor equipment that already speaks Modbus, or the CORE REST API for MES, ERP and BI — both served locally, both included.
INCLUDED IN THIS KIT Licensed to the gatewayCORE Modbus acquisition · REST APIEDG-UPLINK Mobile uplinkEDG-DASH Local dashboardEDG-VTAG Virtual tagsEDG-MBSRV Modbus ServerCLD-VIEW Mobile viewing and alerts→Need trend history on site and a plant picture operators can read at a glance? Step up to K3 — the same gateway, two more modules.
NEXT → K3 -
How It WorksEverything the plant needs day to day runs on the gateway. Cloud history is a second, optional path you add only when a site asks for it.1 →ConnectLink Modbus PLCs, meters, sensors and equipment.2 →ConfigureMap tags and thresholds in the BCS-MX gateway.3 →MonitorDuty view and push alerts on the phone; a local dashboard from K2 up.4IntegrateServe the same tags over REST or Modbus Server on your own network.◆EDGEON SITE — NEVER NEEDS A SUBSCRIPTIONLESI EDGENO ANNUAL FEE♟ModbusTCP / RTU→BCS-MX300 local tags→♧On DutyPhone + browser→
kit♧UpstreamREST - every
kit- ✓
Modbus acquisition and Open REST API K1 · K2 · K3Named, typed, timestamped tags for MES, ERP, BI or AI tools — served on site, no cloud round-trip.
- ✓
Mobile duty view and push alerts K1 · K2 · K3The shift sees status and gets notified without opening a laptop.
- ✓
Local dashboard and Modbus Server K2 · K3Live tiles on any browser on the plant network, and the gateway serving its tags to an existing SCADA or HMI.
- ✓
Local trends and Graphic View K3Trend history and plant-picture screens, held and drawn on the gateway itself.
♟Mobile access is activated once, permanently, per gateway. Each company gets 99 viewer seats at no charge — add people to the duty roster without adding a licence.◆CLOUDABOVE THE PLANT — ADD IT WHEN YOU NEED ITLESI CLOUDSUBSCRIPTION- ✓
Long-term historyBeyond what the gateway retains locally, for year-over-year comparison and audits.
- ✓
Cross-site management viewSeveral plants, one login — for the people who don't walk the floor.
- ✓
Access from outside the plant networkRemote web and mobile access without opening the local network.
- ✓
Nothing on site changesTags, dashboard, alerts and the REST API stay exactly as configured — the cloud reads the same gateway.
◈LESI CLOUD is additive. If a cloud plan lapses, the LESI EDGE kit keeps collecting, displaying, alerting and serving its API exactly as before.System ArchitectureField DevicesModbus TCP PLCs, meters and drives over EthernetModbus RTU Serial devices over RS-485GatewayBCS-MX LESI EDGE software Up to 300 tags
Alarm limitsApplicationsMobile devices Live status view and push notificationsAll kitsMES, ERP, BI and analytics REST API, local networkAll kitsWeb browser Local dashboardK2, K3SCADA, HMI or PLC Modbus TCP ServerK2, K3LESI CLOUD Long-term history, multi-site accessOptionalKit availability shown at right. LESI CLOUD is a separately licensed subscription; local functions do not depend on it. - ✓
-
What's IncludedWhat ships in the box, what runs on the gateway, and what stays optional.▣BCS-MX Industrial Edge GatewayModbus TCP + RTU · 24 VDC · DIN-rail mount▭LESI EDGE On-Device SoftwarePre-installed and licensed to the gateway — yours to keep⇄Open API / RESTAuthenticated endpoint served on your local network▯Mobile AppDuty view and push alerts · iOS and Android✓CORE — on the gatewayK1 · K2 · K3
- ⇅
Modbus TCP / RTU AcquisitionSerial and Ethernet polling in one gateway
- ≡
Connection SettingsDevice, register and scan-rate configuration
- ◔
Communication DiagnosticsLive polling state and error counters
- ⇄
Open API / RESTAuthenticated, on your local network
- ▤
Local Tag CapacityUp to 300 tags on the gateway
▦Software modules by kit level- ▭
EDG-DASH · Live DashboardK2 · K3Live tiles served by the gateway itself
- ▥
Modbus ServerK2 · K3Gateway serves its tags to SCADA, HMI or PLC
- ≈
Virtual TagsK2 · K3Computed values derived from raw tags
- ∿
EDG-TREND · Historical TrendsK3Local trend charts and value lookups on site
- ▦
EDG-GVIEW · Graphic ViewK3Plant-picture screens with live values
- ◇
EDG-EVENT · Event Logic EditorNOT IN A KITOn-gateway rule builder
☁CLOUDLESI CLOUD — optional cloud history, added when you need itSUBSCRIPTION▤Long-term historyBeyond the gateway's local retention, for comparison and audits.◎Cross-site management viewSeveral plants in one login, reachable from outside the plant network.✦AI-assisted reportingScheduled summaries built on cloud history.The kit does not depend on it. If a cloud plan is never bought, or lapses, the gateway keeps collecting, displaying, alerting and serving its API.✓OwnershipGateway and on-device software are a one-time purchase, licensed to that gateway. No renewal is required for local operation or the mobile duty view.▤Tag CapacityUp to 300 local tags per gateway. Capacity is a ceiling, not a commitment — a kit does not have to be filled to be useful.!Site RequirementsRequires Modbus enabled, a register map, 24 VDC power and a network connection — no control-logic changes. Installation, configuration, custom screens and system integration are not included.SpecificationsComputer CPU ARM Cortex-A53, 64-bit quad-core, 1.2 GHz DRAM 1 GB LPDDR2 Storage 32 GB eMMC flash, pre-installed Operating system Embedded Linux Real-time clock Battery-backed, CR2032 coin cell Tags supported 300 (local) Computer Interface Ethernet ports 2 × RJ45, 10/100 Mbps, auto-negotiation Serial 1 × 8-position terminal block USB 2.0 1 × Type-A LED indicators PWR, COM, LINK, RUN, LINK ERR, ERR Ethernet Software Features Industrial protocols Modbus TCP Client
Modbus TCP Server (K2, K3)Integration REST API, authenticated, local network Configuration Web console (HTTPS) Serial Interface Connector 8-position terminal block Serial standard RS-485, 2-wire (pins 1–3) Baud rate 1,200 to 115,200 bps Data bits 7, 8 Stop bits 1, 2 Parity None, Even, Odd Serial Signals Pins 1–3 Data+, Data−, GND Pins 4–8 TxD+/Data+, TxD−/Data−, RxD+, RxD−, GND Serial Software Features Industrial protocols Modbus RTU Master Mobile and Cloud Services Cloud connection LESI CLOUD via EDG-UPLINK, up to 100 tags Mobile platforms iOS, Android Mobile functions Live status view, push notifications, alarm acknowledgment Viewer accounts 99 per company Data refresh 1 minute (mobile app) Historical storage LESI CLOUD subscription (optional) Power Parameters Input voltage 24 VDC Input current 0.5 A max. (nameplate rating) Power connector 3-position terminal block (24V, 0V, PE) Wire range 0.2 to 1.5 mm² Strip length 9 to 10 mm Physical Characteristics Housing Polycarbonate (PC), RAL 5018 Cooling Fanless Dimensions 40 × 100 × 97 mm (1.57 × 3.94 × 3.82 in) Weight Approx. 160 g (0.35 lb) Installation 35 mm DIN rail Environmental Limits Operating temp. 0 to 50°C (32 to 122°F) Storage temp. −20 to 75°C (−4 to 167°F) Storage humidity 95% RH, non-condensing Standards and Certifications RoHS Compliant FCC In progress UL In progress Specifications are based on outline drawing GFPC-0314-001, Rev. V2. Input current is a nameplate rating. Inch, pound and °F values are rounded conversions.LESI EDGE Software ModulesModule Function K1 K2 K3 CORE Modbus acquisition, communication diagnostics, REST API ● ● ● EDG-UPLINK Gateway connection to LESI CLOUD, up to 100 tags ● ● ● CLD-VIEW Mobile live view and push notifications, 99 viewer accounts per company ● ● ● EDG-DASH Local web dashboard served by the gateway – ● ● EDG-VTAG Virtual tags calculated on the gateway – ● ● EDG-MBSRV Modbus TCP Server – ● ● EDG-TREND Local historical trends, multi-signal comparison and data download – – ● EDG-GVIEW Local graphic view with live values – – ● EDG-EVENT Event logic editor – – – ● = included – = not included. EDG-EVENT is not included in any kit. Software is licensed to the gateway.Ordering InformationModel Name PN Description BCS-MX BCS-MX Industrial edge gateway, 1 GB RAM, 32 GB eMMC, 2 × Ethernet, serial, 24 VDC K1 Field Visibility Kit LESI-PKG-K1-001 BCS-MX with LESI EDGE CORE, EDG-UPLINK and CLD-VIEW K2 Integration Kit LESI-PKG-K2-001 BCS-MX with K1 modules plus EDG-DASH, EDG-VTAG and EDG-MBSRV K3 Local SCADA Kit LESI-PKG-K3-001 BCS-MX with K2 modules plus EDG-TREND and EDG-GVIEW LESI CLOUD services are licensed separately. Installation and integration services are not included. - ⇅
-
Why Integrators Standardize on LESIOne configurable platform instead of a custom software project per site or per machine — so monitoring becomes something you can quote, deliver and repeat.Quote the whole monitoring scopeDashboard, mobile alerts and an API exist on day one. The monitoring line item stops being a software risk — you are configuring a product, not estimating development.Repeatable across sitesSame gateway, same commissioning steps, three module scopes. The second site costs your team less than the first, and a junior engineer can follow the same procedure.The service revenue stays yoursInstallation, register mapping, alarm setup, screen building and upstream integration are your scope and your invoice — LESI supplies the platform, not the project.No subscription to defendGateway, on-device software and mobile app are a one-time purchase. Local monitoring does not expire, which is a far easier approval to get signed than a recurring fee.✓What LESI hands you
- ✓
Modbus TCP / RTU acquisitionUp to 300 local tags per gateway, serial and Ethernet in one device.
- ✓
Local dashboard, virtual tags, Modbus ServerK2 and K3 — served by the gateway on the plant network.
- ✓
Graphic view and local trendsK3 — plant picture and multi-signal comparison on site.
- ✓
Mobile duty view and push alertsEvery kit, 99 viewer seats per company, activated once per gateway.
- ✓
Authenticated REST APIEvery kit — the integration surface for MES, ERP or BI.
⇄What stays in your scope- ✓
Installation, panel work and wiringMounting, 24 VDC power, RS-485 and Ethernet runs.
- ✓
Register mapping and alarm setupReading the equipment's register map and configuring the conditions.
- ✓
Custom screens and graphic layoutsBuilding the dashboard and graphic views the customer wants.
- ✓
Upstream integration workConnecting the REST API or Modbus registers to MES, ERP, BI or SCADA.
- ✓
Optional cloud historyA separate subscription, quoted only when the site needs long-term storage.
1Equipment dataModbus access enabled on the equipment, and a register map you can read.2Power and wiring24 VDC power on the DIN rail; Ethernet and / or RS-485 to the devices.3Tag and alarm setupMap the values that matter and configure the alarm conditions.4Network and phonesInternet access and notifications enabled for the mobile features.SELECT THE KIT FOR THE PROJECTStart at the level the site needs today.Same BCS-MX gateway in every kit — move up later without re-doing the tag map. Not sure which kit? Send your equipment list to info@goodlinker.io and we'll recommend one.K1Field VisibilityK2IntegrationK3Local SCADA - ✓
- NEXCOM AIoT Mart Customer Service Email: ecommerce@nexcom.com.tw
-
Kit FitsWhere Each Kit FitsThree applications the same gateway covers — and the level each one usually needs.
Remote machine monitoring1Remote Machine Status Monitoring
PLCs, counters and cycle-time data that the shift can check from any phone — run, idle, alarm.
K1Eyes on the floor. Nothing upstream needs the data yet.
OUTCOMES- ✓Faster response to downtime
- ✓Machine-state and cycle-time data to support OEE analysis
- ✓Line visibility without a PC on the floor
Does anyone outside the plant floor need this data?
NO → K1A screen and a phone are enough.
Remote energy monitoring2Remote Energy Monitoring Across Panels
Main meters, panel sub-meters and machine-level power, totalled and handed to the systems that report on them.
K2Virtual Tags total the meters; REST and Modbus Server feed the report.
OUTCOMES- ✓Identify abnormal energy peaks sooner
- ✓See usage by zone or machine
- ✓Energy figures reach ERP or BI without middleware
Does another system — MES, ERP, BI, SCADA — need to read it?
YES → K2REST Out, Modbus Server, Virtual Tags.
Remote utility & environmental3Remote Utility & Environmental Monitoring
Temperature, humidity, pH, flow and level across tanks, pumps and treatment stages.
K3A process reads better as a plant picture — and excursions need trends on site.
OUTCOMES- ✓Spot excursions sooner
- ✓Fewer manual round checks
- ✓Local trend history for on-site investigation
Do operators need trend history and a plant picture on site?
YES → K3Local trends and Graphic View.
⛨FOR INTEGRATORS
& MACHINE BUILDERSWiring a panel is the easy part. Handing over a dashboard, an API and a mobile app on the same day is not. LESI lets you engineer the whole monitoring scope — on a retrofit project or built into every machine you ship — while installation, configuration and integration revenue stays yours.
-
K2 (Integration)K2 KIT 02INTEGRATION KIT · MOST DEPLOYEDBring Equipment Data Into Your Own SystemsEverything in K1, plus the three things an integrator usually needs on site: a dashboard served by the gateway itself, calculated tags, and a Modbus Server so the SCADA or HMI already on the panel can read what LESI collects.✓Everything in K1 included ▭Local dashboard ⇄Virtual tags ▣Modbus ServerEDG-DASH Local Web dashboard on the gateway

Actual on-device dashboard, shown in an example configuration. Live values grouped by area or machine; out-of-range tags flag themselves. Opened from any browser on the plant network — no cloud in the path.
WHO IT’S FORIntegrators and plant engineers who need equipment data inside SCADA, HMI, MES or ERP.
▭Local Dashboard
Live tiles grouped by line, area or equipment. One URL for the office PC, the panel display and the tablet on the floor.
EDG-DASH⇄Virtual Tags
Total meters, convert units, derive condition flags — calculated at the gateway, so every consumer reads the same number.
EDG-VTAG▣Modbus Server
Map configured tags to registers and let an existing SCADA, HMI or PLC poll the gateway — no middleware to write.
EDG-MBSRV⌬Upstream systems can take either road: Modbus Server for the plant-floor equipment that already speaks Modbus, or the CORE REST API for MES, ERP and BI — both served locally, both included.
INCLUDED IN THIS KIT Licensed to the gatewayCORE Modbus acquisition · REST APIEDG-UPLINK Mobile uplinkEDG-DASH Local dashboardEDG-VTAG Virtual tagsEDG-MBSRV Modbus ServerCLD-VIEW Mobile viewing and alerts→Need trend history on site and a plant picture operators can read at a glance? Step up to K3 — the same gateway, two more modules.
NEXT → K3 -
How It WorksHow It WorksEverything the plant needs day to day runs on the gateway. Cloud history is a second, optional path you add only when a site asks for it.1 →ConnectLink Modbus PLCs, meters, sensors and equipment.2 →ConfigureMap tags and thresholds in the BCS-MX gateway.3 →MonitorDuty view and push alerts on the phone; a local dashboard from K2 up.4IntegrateServe the same tags over REST or Modbus Server on your own network.◆EDGEON SITE — NEVER NEEDS A SUBSCRIPTIONLESI EDGENO ANNUAL FEE♟ModbusTCP / RTU→BCS-MX300 local tags→♧On DutyPhone + browser→
kit♧UpstreamREST - every
kit- ✓
Modbus acquisition and Open REST API K1 · K2 · K3Named, typed, timestamped tags for MES, ERP, BI or AI tools — served on site, no cloud round-trip.
- ✓
Mobile duty view and push alerts K1 · K2 · K3The shift sees status and gets notified without opening a laptop.
- ✓
Local dashboard and Modbus Server K2 · K3Live tiles on any browser on the plant network, and the gateway serving its tags to an existing SCADA or HMI.
- ✓
Local trends and Graphic View K3Trend history and plant-picture screens, held and drawn on the gateway itself.
♟Mobile access is activated once, permanently, per gateway. Each company gets 99 viewer seats at no charge — add people to the duty roster without adding a licence.◆CLOUDABOVE THE PLANT — ADD IT WHEN YOU NEED ITLESI CLOUDSUBSCRIPTION- ✓
Long-term historyBeyond what the gateway retains locally, for year-over-year comparison and audits.
- ✓
Cross-site management viewSeveral plants, one login — for the people who don't walk the floor.
- ✓
Access from outside the plant networkRemote web and mobile access without opening the local network.
- ✓
Nothing on site changesTags, dashboard, alerts and the REST API stay exactly as configured — the cloud reads the same gateway.
◈LESI CLOUD is additive. If a cloud plan lapses, the LESI EDGE kit keeps collecting, displaying, alerting and serving its API exactly as before.System ArchitectureField DevicesModbus TCP PLCs, meters and drives over EthernetModbus RTU Serial devices over RS-485GatewayBCS-MX LESI EDGE software Up to 300 tags
Alarm limitsApplicationsMobile devices Live status view and push notificationsAll kitsMES, ERP, BI and analytics REST API, local networkAll kitsWeb browser Local dashboardK2, K3SCADA, HMI or PLC Modbus TCP ServerK2, K3LESI CLOUD Long-term history, multi-site accessOptionalKit availability shown at right. LESI CLOUD is a separately licensed subscription; local functions do not depend on it. - ✓
-
Kit ContentsWhat's IncludedWhat ships in the box, what runs on the gateway, and what stays optional.▣BCS-MX Industrial Edge GatewayModbus TCP + RTU · 24 VDC · DIN-rail mount▭LESI EDGE On-Device SoftwarePre-installed and licensed to the gateway — yours to keep⇄Open API / RESTAuthenticated endpoint served on your local network▯Mobile AppDuty view and push alerts · iOS and Android✓CORE — on the gatewayK1 · K2 · K3
- ⇅
Modbus TCP / RTU AcquisitionSerial and Ethernet polling in one gateway
- ≡
Connection SettingsDevice, register and scan-rate configuration
- ◔
Communication DiagnosticsLive polling state and error counters
- ⇄
Open API / RESTAuthenticated, on your local network
- ▤
Local Tag CapacityUp to 300 tags on the gateway
▦Software modules by kit level- ▭
EDG-DASH · Live DashboardK2 · K3Live tiles served by the gateway itself
- ▥
Modbus ServerK2 · K3Gateway serves its tags to SCADA, HMI or PLC
- ≈
Virtual TagsK2 · K3Computed values derived from raw tags
- ∿
EDG-TREND · Historical TrendsK3Local trend charts and value lookups on site
- ▦
EDG-GVIEW · Graphic ViewK3Plant-picture screens with live values
- ◇
EDG-EVENT · Event Logic EditorNOT IN A KITOn-gateway rule builder
☁CLOUDLESI CLOUD — optional cloud history, added when you need itSUBSCRIPTION▤Long-term historyBeyond the gateway's local retention, for comparison and audits.◎Cross-site management viewSeveral plants in one login, reachable from outside the plant network.✦AI-assisted reportingScheduled summaries built on cloud history.The kit does not depend on it. If a cloud plan is never bought, or lapses, the gateway keeps collecting, displaying, alerting and serving its API.✓OwnershipGateway and on-device software are a one-time purchase, licensed to that gateway. No renewal is required for local operation or the mobile duty view.▤Tag CapacityUp to 300 local tags per gateway. Capacity is a ceiling, not a commitment — a kit does not have to be filled to be useful.!Site RequirementsRequires Modbus enabled, a register map, 24 VDC power and a network connection — no control-logic changes. Installation, configuration, custom screens and system integration are not included.SpecificationsComputer CPU ARM Cortex-A53, 64-bit quad-core, 1.2 GHz DRAM 1 GB LPDDR2 Storage 32 GB eMMC flash, pre-installed Operating system Embedded Linux Real-time clock Battery-backed, CR2032 coin cell Tags supported 300 (local) Computer Interface Ethernet ports 2 × RJ45, 10/100 Mbps, auto-negotiation Serial 1 × 8-position terminal block USB 2.0 1 × Type-A LED indicators PWR, COM, LINK, RUN, LINK ERR, ERR Ethernet Software Features Industrial protocols Modbus TCP Client
Modbus TCP Server (K2, K3)Integration REST API, authenticated, local network Configuration Web console (HTTPS) Serial Interface Connector 8-position terminal block Serial standard RS-485, 2-wire (pins 1–3) Baud rate 1,200 to 115,200 bps Data bits 7, 8 Stop bits 1, 2 Parity None, Even, Odd Serial Signals Pins 1–3 Data+, Data−, GND Pins 4–8 TxD+/Data+, TxD−/Data−, RxD+, RxD−, GND Serial Software Features Industrial protocols Modbus RTU Master Mobile and Cloud Services Cloud connection LESI CLOUD via EDG-UPLINK, up to 100 tags Mobile platforms iOS, Android Mobile functions Live status view, push notifications, alarm acknowledgment Viewer accounts 99 per company Data refresh 1 minute (mobile app) Historical storage LESI CLOUD subscription (optional) Power Parameters Input voltage 24 VDC Input current 0.5 A max. (nameplate rating) Power connector 3-position terminal block (24V, 0V, PE) Wire range 0.2 to 1.5 mm² Strip length 9 to 10 mm Physical Characteristics Housing Polycarbonate (PC), RAL 5018 Cooling Fanless Dimensions 40 × 100 × 97 mm (1.57 × 3.94 × 3.82 in) Weight Approx. 160 g (0.35 lb) Installation 35 mm DIN rail Environmental Limits Operating temp. 0 to 50°C (32 to 122°F) Storage temp. −20 to 75°C (−4 to 167°F) Storage humidity 95% RH, non-condensing Standards and Certifications RoHS Compliant FCC In progress UL In progress Specifications are based on outline drawing GFPC-0314-001, Rev. V2. Input current is a nameplate rating. Inch, pound and °F values are rounded conversions.LESI EDGE Software ModulesModule Function K1 K2 K3 CORE Modbus acquisition, communication diagnostics, REST API ● ● ● EDG-UPLINK Gateway connection to LESI CLOUD, up to 100 tags ● ● ● CLD-VIEW Mobile live view and push notifications, 99 viewer accounts per company ● ● ● EDG-DASH Local web dashboard served by the gateway – ● ● EDG-VTAG Virtual tags calculated on the gateway – ● ● EDG-MBSRV Modbus TCP Server – ● ● EDG-TREND Local historical trends, multi-signal comparison and data download – – ● EDG-GVIEW Local graphic view with live values – – ● EDG-EVENT Event logic editor – – – ● = included – = not included. EDG-EVENT is not included in any kit. Software is licensed to the gateway.Ordering InformationModel Name PN Description BCS-MX BCS-MX Industrial edge gateway, 1 GB RAM, 32 GB eMMC, 2 × Ethernet, serial, 24 VDC K1 Field Visibility Kit LESI-PKG-K1-001 BCS-MX with LESI EDGE CORE, EDG-UPLINK and CLD-VIEW K2 Integration Kit LESI-PKG-K2-001 BCS-MX with K1 modules plus EDG-DASH, EDG-VTAG and EDG-MBSRV K3 Local SCADA Kit LESI-PKG-K3-001 BCS-MX with K2 modules plus EDG-TREND and EDG-GVIEW LESI CLOUD services are licensed separately. Installation and integration services are not included. - ⇅
-
Why LESIWhy Integrators Standardize on LESIOne configurable platform instead of a custom software project per site or per machine — so monitoring becomes something you can quote, deliver and repeat.Quote the whole monitoring scopeDashboard, mobile alerts and an API exist on day one. The monitoring line item stops being a software risk — you are configuring a product, not estimating development.Repeatable across sitesSame gateway, same commissioning steps, three module scopes. The second site costs your team less than the first, and a junior engineer can follow the same procedure.The service revenue stays yoursInstallation, register mapping, alarm setup, screen building and upstream integration are your scope and your invoice — LESI supplies the platform, not the project.No subscription to defendGateway, on-device software and mobile app are a one-time purchase. Local monitoring does not expire, which is a far easier approval to get signed than a recurring fee.✓What LESI hands you
- ✓
Modbus TCP / RTU acquisitionUp to 300 local tags per gateway, serial and Ethernet in one device.
- ✓
Local dashboard, virtual tags, Modbus ServerK2 and K3 — served by the gateway on the plant network.
- ✓
Graphic view and local trendsK3 — plant picture and multi-signal comparison on site.
- ✓
Mobile duty view and push alertsEvery kit, 99 viewer seats per company, activated once per gateway.
- ✓
Authenticated REST APIEvery kit — the integration surface for MES, ERP or BI.
⇄What stays in your scope- ✓
Installation, panel work and wiringMounting, 24 VDC power, RS-485 and Ethernet runs.
- ✓
Register mapping and alarm setupReading the equipment's register map and configuring the conditions.
- ✓
Custom screens and graphic layoutsBuilding the dashboard and graphic views the customer wants.
- ✓
Upstream integration workConnecting the REST API or Modbus registers to MES, ERP, BI or SCADA.
- ✓
Optional cloud historyA separate subscription, quoted only when the site needs long-term storage.
1Equipment dataModbus access enabled on the equipment, and a register map you can read.2Power and wiring24 VDC power on the DIN rail; Ethernet and / or RS-485 to the devices.3Tag and alarm setupMap the values that matter and configure the alarm conditions.4Network and phonesInternet access and notifications enabled for the mobile features.SELECT THE KIT FOR THE PROJECTStart at the level the site needs today.Same BCS-MX gateway in every kit — move up later without re-doing the tag map. Not sure which kit? Send your equipment list to info@goodlinker.io and we'll recommend one.K1Field VisibilityK2IntegrationK3Local SCADA - ✓
-
After-sales service
-
Contact UsNEXCOM AIoT Mart Customer Service Email: ecommerce@nexcom.com.tw
Industrial Edge Monitoring Platform
LESI EDGE
Industrial edge monitoring kits — by GoodLinker
Configured, not developed. Modbus in, REST out.
Remote Monitoring Kit
for Modbus Equipment
Gateway, on-device software and mobile app in one kit. Buy it once: live status on every phone on shift, data ready for your MES, BI or AI tools. Cloud history is optional.
(LESI EDGE gateway)
Connect Existing Machines
Modbus TCP or RTU. No control-logic changes.
Nothing to Develop
Dashboard, alerts and the mobile app are already built.
AI-Ready Data, Open REST API
Named, timestamped tags for your AI, MES or BI.
No Subscription to Stay Running
Local monitoring does not expire with a cloud plan.
Three kits — K1 Field Visibility, K2 Integration, K3 Local SCADA — all built on the same gateway.
Three Kits. One Remote Monitoring Platform.
All three kits are one-time purchases. Nothing below stops working when a cloud plan lapses.
Field Visibility Kit
See the line today — live values on the floor, alerts in their pocket.
Integration Kit
Feed the systems upstairs, and keep a screen on the floor.
Local SCADA Kit
Supervise the plant on site — trend history and a plant picture.
ADD-ON
ADD-ON
ADD-ON
Cloud is optional — never required. Long-term cloud history is a separate subscription, added only when a site needs it. No kit depends on it to keep running.